DAS NX - GE Networx - Support Information
Arming the System
Disarming the system
Bypassing (Switching off) Zones on Arming
Force Arming the alarm
Home Arming the alarm
Viewing the Alarm Memory
Viewing User Codes
Changing User Codes
Setting User Access Privileges
Turning On / Off Zone chimes
Alarm Troubleshooting
Testing the Alarm System
Setting the Time and Date
Arming the Panel
1) Enter a valid user code.
2) The ARMED and EXIT LED / LCD Segment will now Illuminate, and the Exit delay will commence.
3) The EXIT Light will flash rapidly for the last 10 seconds of the exit delay.
Top
Disarming the Panel
1) Enter a valid user code.
2) The ARMED light will extinguish when the panel is disarmed.
Top
Bypassing (Switching Off) Zones on Arming
Manual Bypass Programming allows you to program the
alarm system to ignore (deactivate) specified zones the
next time the system is armed.
For example, you may wish to bypass certain zones when workers are renovating part
of your establishment.
Please note that a Fire Zone cannot be bypassed.
1) Press the [BYPASS] Button.
2) Enter your access code.
3) Select the Zones that you wish to bypass by selecting the 2 Digit Zone Number.
4) Press the [BYPASS] button again to Save the Bypassed zone entries.
5) The selected zones will be bypassed next time the system is armed.
Top
Force Arming the alarm
Force arming allows you to rapidly arm the system without
waiting for all zones in the system to close.
During Force arming, a Force zone is considered "deactivated" until it
closes, after which the system will arm that zone.
Force arming is commonly used when a motion detector is
protecting the area occupied by a keypad.
For example, when arming the system from within a Force zone, the
system will allow you to arm even if the zone is open, and
the system will arm the zone once it closes.
1) Press the [ON] button.
3) The ARMED LED / LCD Segment will now Illuminate, and the Exit delay will commence.
Top
Home (Partial) Arming the alarm
This method allows you to remain in the protected area
while partially arming the system.
Home zones are zones that are bypassed when Partial arming.
For example, when you go to sleep at night, doors and windows can be armed
without arming other zones like motion detectors.
1) Press the [PARTIAL] button.
2) The BYPASS LED / LCD Segment will now Illuminate.
Top
Viewing the Alarm Memory
If a zone has been triggered whilst the alarm system is in its Armed state,
To display the zones have been triggered,
1) Press the star [*] Button
3) Press the [3] Button
2) the zones that have been triggered will Be displayed on the keypad.
Top
Viewing User Codes
To view user codes entered in the system, you will first need the Master, or Installer Code.
1) Press the star [*] button, followed by the [5] button.
2) Enter a valid installer or master code. (Default code is 1234)
The system will prompt you for the user number to view / change.
3) Enter the user number (01-34)
Note : User 01 is the Installer Code.
Note : User 02 is the Master Code.
Note : User 03 is the First User Code for the system.
4) The first Digit of the user code will be displayed.
5) Press the star [*] button to view the next digit.
6) Press the hash [#] button to exit this mode.
Top
Changing User Codes
To change user access codes, you will first require the Master code.
1) Press the star [*] button, followed by the [5] button.
2) Enter a valid installer or master code. (Default code is 1234)
3) Enter the user number (01-34)
Note : User 01 is the Installer Code.
Note : User 02 is the Master Code.
Note : User 03 is the First User Code for the system.
4) Enter the new code for the user selected (The code should be 4 digits long.)
5) Press the Hash [#] button.
6) The code for the selected user will be changed, and the system will exit this mode.
NOTE : Pressing the [CHIME] button 5 times, instead of entering a new user code will delete the user from the system.
Top
Setting Chime Zones
This feature allows you to enable or disable the chime mode.
A Chime-enabled zone will advise you
every time it is opened by causing your keypad to emit Chime tone (Ding Dong).
Press the [CHIME] Button to enable or disable the chime feature.
NOTE : Chime zones MUST be programmed by the alarm installer for the chime feature to work.
Top
Alarm Trouble Codes
If a system fault has been detected, the Service Indicator will be on.
To determine the system fault,
Press the star [*] button, followed by the 2 button.
The Fault Number will be displayed as a Zone number on the Keypad.
Light 1 - Press the 1 button for further fault codes.
- 1 Over current fault.
- 2 Siren Trouble.
- 3 Box Tamper.
- 4 Expander Power.
- 5 Expander Low Battery.
- 6 Expander Box Tamper.
- 7 Expander Trouble.
- 8 Reserved.
Press Hash [#] to return to 1-8 Trouble Lights.
Light 2 - Zone Tamper.
Light 3 - Zone Low Battery.
Light 4 - Zone loss of supervision.
Light 5 - Zone trouble.
Light 6 - Reserved.
Light 7 - Communication Fault (Check phone line dial tone, and Communication settings).
Light 8 - Date and Time Loss (Program the Date and Time to reset this error).
Top
Setting the Time and Date
Setting the Date
If the alarm panel has lost power, it may require the system time and date to be set.
1) Press star [*], then 9, then 6.
2) Enter the Master code.
3) Enter the day of the week, (Sun=1, Mon=2, Tue=3, Wed=4, Thu=5, Fri=6, Sat=7.
4) Enter the Month, as a 2 digit number (MM) E.g. Jul would be 07.
5) Enter the Day of the Month, as a 2 digit number (DD).
6) Enter the Year, as a 2 digit number (YY) E.g. 2005 would be 05.
Setting the Time
If the alarm panel has lost power, it may require the system time and date to be set.
1) Press star [*], then 9, then 7.
2) Enter the Master code.
3) Enter the current hour, as a 2 digit (24 Hour) number (HH) E.g. 11:00pm would be 23.
4) Enter the current minute, as a 2 digit number (MM).
Top
Testing the System
Walk Test Mode
1) Press the star [*] button, followed by the [CHIME] button.
2) Enter the master code. (Default code is 1234)
3) Once a sensor is triggered, the siren will sound briefly.
4) Enter the master code again to disable walk test mode. (Default code is 1234)
Top
Panel Information used under license from Pocket Docs - Security Industry Supplies Sydney Australia